Product Overview

Pneumatic angle seated valve has small flow resistance, large flow and no water hammer, widely used
in machinery and electronics industry, petrochemicals, energy and metallurgy, urban construction and
environmental protection as well as other industries like pharmaceutical, textile, dyeing and printing, 
tobacco, rubber, etc., owning obvious unique advantages in the automatic control of fluid.

Features

01. Nominal pressure: PN16bar
02. Applicable medium temp.: Ⅲb: -40~150℃, Ⅳb: -40~250℃
03. Ambient temp.: -30~60℃
04. Valve body material: Normal---SS304 (code: B)
                                        special---SS316 (code: R), SS316L (code: L)
05. Sealing material: Normal---PTFE (code: P) (medium temp.: Ⅲb: -40~150℃)
                                  special---PPL (code: P) (medium temp.: Ⅳb: -40~250℃)
06. Sealing material of cylinder piston: Normal---NBR (code: N)
                                                               special---VITON (code: V) 
07. Leakage: 0ml/min
08. Control air source pressure: Neutral gas, normal 5~8bar, special 3~5bar
09. Long life: Service life is 2~5 times longer than solenoid valve and 10~20 times longer than 
      pneumatic ball valve
10. Small flow resistance: Adopt the design concept of reducing flow resistance
11. Low cost: 30~50% cheaper than pneumatic ball valve 
12. Large flow: 1.5~2 times larger than solenoid valve
13. Water Hammer free: Fast open/closed speed, unique structure can eliminate 
      water hammer
14. Back pressure resistance: The maximum back pressure can reach 10bar (DN15)
15. High frequency: Applicable for high frequency working conditions, the maximum
      action frequency is 20 times/min
16. Wide application: No special requirements for cleanness and kinematic viscosity of
      the medium 
17. With visual valve position indicator
18. The flow direction of medium should be consistent with the arrow direction on the 
      valve body
19. Manual device and valve position signal output device optional 
20. Mounted at any angle, keep cylinder vertically upward&installed horizontally 
      which may extend life span 

Protection cover selection principle

  1. Double acting R type stainless steel actuator must be equipped with protection cover 
  2. Single acting normally open R typestainless steel actuator must be equipped with protection cover 
  3. Single acting normally closed type actuator can be optionally equipped with protection cover
  4. L type actuator without protection cover

Structure Diagram

Parameter and Dimension 【Equipped with RQ Series Actuator, PN16bar】

Notes:

  1. The thread connection is ZG=PT=Rc by default and can be customized according to users´ requirements, such as G=Rp, NPT and so on.
  2. The flange is manufactured according to JB/T79-1994 standard by default and can also be manufactured according to the standards specified by users, such as GB/T9124, HG/T20592, ANSI, JIS, DIN and other standards.  
  3. *indicates aluminum alloy actuator.
  4. The configuration of the above cylinder is for medium pressure: 0~8bar, for 8~16bar type, actuator should be configured with a one-increment larger cylinder.

Parameter and Dimension 【Equipped with LA/LQ Series Actuator, PN16bar】

Notes:

  1. The thread connection is ZG=PT=Rc by default and can be customized according to users´ requirements, such as G=Rp, NPT and so on.
  2. The flange is manufactured according to JB/T79-1994 standard by default and can also be manufactured according to the standards specified by users, such as GB/T9124, HG/T20592, ANSI, JIS, DIN and other standards.  

Control Schematic Diagram 

1. Normally closed single acting type control principle and air source wiring diagram (diagram 1) 

Notes:

(1) For pneumatic solenoid valve, please choose 3/2 way, e.g. our Z1732-04 solenoid valve.
(2) Actuator air inlet 2 connects to air source. Install silencer at air-vent 1.

2. Normally open single acting type control principle and air source wiring diagram (diagram 2) 

Notes:

(1) For pneumatic solenoid valve, please choose 3/2 way, e.g. our Z1732-04 solenoid valve.
(2) Actuator air inlet 1 connects to air source. Install silencer at air-vent 2.

3. Double acting type control principle and air source wiring diagram (diagram 3) 

Notes:

(1) For pneumatic solenoid valve, please choose 5/2 way, e.g. our Z1753-04 solenoid valve.
(2) When air enters air inlet 1, pneumatic valve closes, port 2 is air vent. When port 2 becomes air inlet, port 1 is air vent, pneumatic valve opens.

 

Note: In explosive atmosphere, please select explosion-proof solenoid valve! 

Exploded Diagram&Component and Material Table

Keywords: YS, YK, YH, YF Series Stainless Steel Pneumatic Angle Seated Valve 〈Open/Closed or Regulating Type〉

Online Message


logo

SHANGHAI BEST AUTOMATION TECHNOLOGY Co.,Ltd.

HQ Add: No.3131, Jinshajiang Road, Jiading District, Shanghai, China

Domestic Sales Center: 8th Floor, Oriental Auto Parts City 3rd New Office Building, No.35, Dingbian Road, Jiading District, Shanghai, China

Phone: 021-57654321, 52751111

Zip Code: 201824


Foreign Trade Dept.: Room 813, 8th Floor, Oriental Auto Parts City 3rd New Office Building, No.35, Dingbian Road, Jiading District, Shanghai, China

Foreign Trade Hotline: 0086-21-66123456, 0086-21-66554433

Foreign Trade QQ: 2184211527, 3688575471, 1038330264, 1825023587

WeChat: 0086-18801801398, 0086-18801801318

               0086-18801801308, 0086-18817946985

WhatsApp: 0086-18801801398, 0086-18801801318, 0086-18801801308

wx
ma
a

WeChat

  • 1Pollyanna
  • 1Vivian
  • 1
    Yuki
  • 1
    Victor

QQ

Messenge

TOP


Copyright© 2024 Shanghai Best Automation Technology Co., Ltd. All Rights Reserved   Website:66123456.com | bestautovalve.com |  SEO   Business License

安安新材料