Products
Technical
G2001 Straight Through Type, G2007 Angle Type Carbon Steel, Stainless Steel Series Manual Backwash Filter < Filter Valve >
Product documents:
-
File size: 267.6KB
-
File size: 739.0KB
Foreign Trade E-mails:
sale01@bestautovalve.com
sale02@bestautovalve.com
sale03@bestautovalve.com
sale06@bestautovalve.com
① EARNEST RIGOROUS DEDICATED PROFESSIONAL
② Source Goods, Powerful Factories, More Cost-effective
③ Ten Production Capacity in China, Stable Quality
Product Details
Features
01. It can filter the debris in the fluid, and can also automatically backwash the debris on the filter screen, so it is also known as the automatic
sewage filter
02. Only need to rotate the handle of the backwash control valve 90 degrees, which can be backwashed and easy to operate
03. Diameter range: DN25~800
04. The viscosity of the medium should generally ≤ 50CSt (mm2/s)
05. The medium flow must be consistent with the direction of the arrow on the valve body
06. Body material: Cast steel WCB (code: C), SS304 (code: B),
SS316 (code: R), SS316L (code: L)
07. Filter mesh: Normal 10 mesh (2000μm), other customization
08. Applicable medium temperature: Normal Ib: -9~80℃ special carbon steel
Ⅲa: -29~150℃, stainless steel Ⅲb: -40~150℃
09. In order to facilitate the observation of whether the filter is blocked and the outlet flow, please install a pressure gauge at the outlet
10. Nominal pressure: Normal PN10bar, special PN16, 25, 40bar, minimum working pressure 1bar
11. The sewage outlet should generally be installed downward, and connect a sewage control valve (such as a globe valve, ball valve, etc.),
when working normally, please close the sewage control valve (otherwise the sewage port it will circulate or leak all the time), when
backwashing is required, please open the sewage control valve (otherwise the sewage cannot be discharged)
12. Installation method: Horizontal installation of the sewage outlet downward, otherwise it cannot be effectively discharged
Working Principle (G2001 Straight Through Type)

How it Works:
In normal operation, the backwash control valve 1 is opened, and the fluid moves outside the filter cylinder under the block of the baffle 5. after passing through the filter net 3,flow to the outlet, at this time the blowdown control valve 7 is closed. in the automatic blowdown state, the backwash control valve 1 is closed, and the fluid is blocked by the butterfly plate 2 directly to the filter cylinder, and then through the filter net 3 from the outside the internal movement automatically flushes the debris on the filter net 3, and then flows to the sewage outlet 6, at this time the sewage control valve 7 is open, and the sewage passes through the sewage outlet 6 blowdown control valve 7 discharge. At the end of discharge, please close the discharge control valve in time 7.automatic blowdown, there is still some fluid flow to the outlet, so the outlet should be installed with on-off valves (such as globe valves, gate valves, ball valves, butterfly valves, etc.), turn it off during blowdown to improve backwash efficiency and avoid unfiltered fluid flow to the line behind the valve.
Special Configuration

External Dimension (Pn10bar)

Notes:
- *sign indicates the external thread connection, the other is flange connection.
- The flange is manufactured according to JB/T79-1994 standard by default, and can also be manufactured according to user-specified standards, such as GB/T9124, HG/T20592, ANSI, JIS, DIN, etc
- The flow rate is determined by water quality and filtration accuracy, and the flow rate in the table is the value when the number of filter mesh is 2000μm, for reference only.
Type Specification

Keywords: G2001 Straight Through Type, G2007 Angle Type Carbon Steel, Stainless Steel Series Manual Backwash Filter < Filter Valve >
Online Message
Recommended Products
Welcome to BEST AUTOVALVE.
SHANGHAI BEST AUTOMATION TECHNOLOGY Co.,Ltd.
HQ Add: No.3131, Jinshajiang Road, Jiading District, Shanghai, China
Domestic Sales Center: 8th Floor, Oriental Auto Parts City 3rd New Office Building, No.35, Dingbian Road, Jiading District, Shanghai, China
Phone: 021-57654321, 52751111
Zip Code: 201824
Foreign Trade Dept.: Room 813, 8th Floor, Oriental Auto Parts City 3rd New Office Building, No.35, Dingbian Road, Jiading District, Shanghai, China
Foreign Trade Hotline: 0086-21-66123456, 0086-21-66554433
Foreign Trade QQ: 2184211527, 3688575471, 1038330264, 1825023587
WeChat: 0086-18801801398, 0086-18801801318
0086-18801801308, 0086-18817946985
WhatsApp: 0086-18801801398, 0086-18801801318, 0086-18801801308
EARNEST · RIGOROUS · DEDICATED · PROFESSIONAL
Ten Production Capacity in China, Stable Quality
Ten Honesty Enterprises judged by government of Shanghai in China
mail link ma2
Pollyannasale01@bestautovalve.com
Pollyannasale02@bestautovalve.com
Viviansale03@bestautovalve.com
Victorsale07@bestautovalve.com
Copyright© 2024 Shanghai Best Automation Technology Co., Ltd. All Rights Reserved Website:66123456.com | bestautovalve.com | SEO Business License





Pollyanna
Vivian